CVE Program partner
BD
Becton, Dickinson and Company (BD)
CVEs, 365 days022 all time, 0 rejected
Quality-median 99%
CVSS by the CNA-share of records
CWE-share of records
Affected versions-not n/a or unspecified
CVSS added by CISA-lower is better
| Organisation | Becton, Dickinson and Company (BD) |
| Role | CNA |
| Type | Vendor |
| Reports to | icscert → CISA |
| Scope | BD software-enabled medical devices only. |
| Advisories | https://cybersecurity.bd.com/bulletins-and-patches |
Latest CVEs · RSS
- CVE-2024-10476 2024-12-17 · CVSS 8.0Default credentials are used in the above listed BD Diagnostic Solutions products. If exploited, threat actors may be able to access, modify or delete data, inc
- CVE-2023-29066 2023-11-28 · CVSS 3.2The FACSChorus software does not properly assign data access privileges for operating system user accounts. A non-administrative OS account can modify informati
- CVE-2023-29065 2023-11-28 · CVSS 4.1The FACSChorus software database can be accessed directly with the privileges of the currently logged-in user. A threat actor with physical access could potenti
- CVE-2023-29064 2023-11-28 · CVSS 4.1The FACSChorus software contains sensitive information stored in plaintext. A threat actor could gain hardcoded secrets used by the application, which include t
- CVE-2023-29063 2023-11-28 · CVSS 2.4The FACSChorus workstation does not prevent physical access to its PCI express (PCIe) slots, which could allow a threat actor to insert a PCI card designed for
- CVE-2023-29062 2023-11-28 · CVSS 3.8The Operating System hosting the FACSChorus application is configured to allow transmission of hashed user credentials upon user action without adequately valid
- CVE-2023-29061 2023-11-28 · CVSS 5.2There is no BIOS password on the FACSChorus workstation. A threat actor with physical access to the workstation can potentially exploit this vulnerability to ac
- CVE-2023-29060 2023-11-28 · CVSS 5.4The FACSChorus workstation operating system does not restrict what devices can interact with its USB ports. If exploited, a threat actor with physical access to
- CVE-2023-30565 2023-07-13 · CVSS 3.5An insecure connection between Systems Manager and CQI Reporter application could expose infusion data to an attacker.
- CVE-2023-30564 2023-07-13 · CVSS 6.9Alaris Systems Manager does not perform input validation during the Device Import Function.
- CVE-2023-30563 2023-07-13 · CVSS 8.2A malicious file could be uploaded into a System Manager User Import Function resulting in a hijacked session.
- CVE-2023-30562 2023-07-13 · CVSS 6.7A GRE dataset file within Systems Manager can be tampered with and distributed to PCUs.
- CVE-2023-30561 2023-07-13 · CVSS 6.1The data flowing between the PCU and its modules is insecure. A threat actor with physical access could potentially read or modify data by attaching a specially
- CVE-2023-30560 2023-07-13 · CVSS 6.8The configuration from the PCU can be modified without authentication using physical connection to the PCU.
- CVE-2023-30559 2023-07-13 · CVSS 5.2The firmware update package for the wireless card is not properly signed and can be modified.
- CVE-2022-47376 2023-06-13The Alaris Infusion Central software, versions 1.1 to 1.3.2, may contain a recoverable password after the installation. No patient health data is stored in the
- CVE-2022-43557 2022-12-05 · CVSS 5.3The BD BodyGuard™ infusion pumps specified allow for access through the RS-232 (serial) port interface. If exploited, threat actors with physical access, specia
- CVE-2022-40263 2022-11-04 · CVSS 6.6BD Totalys MultiProcessor, versions 1.70 and earlier, contain hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensiti
- CVE-2022-30277 2022-06-01 · CVSS 5.7BD Synapsys™, versions 4.20, 4.20 SR1, and 4.30, contain an insufficient session expiration vulnerability. If exploited, threat actors may be able to access, mo
- CVE-2022-22767 2022-06-01 · CVSS 8.8Specific BD Pyxis™ products were installed with default credentials and may presently still operate with these credentials. There may be scenarios where BD Pyxi
- CVE-2022-22765 2022-02-12 · CVSS 8.0BD Viper LT system, versions 2.0 and later, contains hardcoded credentials. If exploited, threat actors may be able to access, modify or delete sensitive inform
- CVE-2022-22766 2022-02-11 · CVSS 7.0Hardcoded credentials are used in specific BD Pyxis products. If exploited, threat actors may be able to gain access to the underlying file system and could pot